It is almost a common phenomenon on ship to experience difficulties while starting the boiler plant onboard ships. There can be several reasons for the failure in staring of a boiler. In this presentation let us look at the most common reasons for “Boiler not Starting”..
1) Burner Fuel Inlet Valve is in close position:
The fuel line for boiler’s burner consists of several valves located at fuel tank, pumps suction, discharge valve, or valve before the boiler burner. Any of these can be in closed position resulting in starvation of fuel.
2) Choked/Clogged line filter at the inlet of the fuel line for burner:
If the system runs in heavy oil then there are chances of filters in the line getting choke. To avoid this, boiler system are normally built for changeover from diesel to heavy oil during starting and heavy to diesel during stopping. This keeps the filter and the fuel line clean.
3) Solenoid valve in the fuel supply line is malfunctioning:
Nowadays most of the system adopts advance automation, but their can be a possibility wherein the solenoid in the fuel supply line is malfunctioning and not opening.
4) Boiler fuel supply pump is not running:
There are two main reasons for fuel pump not running. Normally when the pumps are in pairs, the change over auto system is kept in manual position, and if the operating pump trips, the stand by pump will not start automatically. Another reason is tripping of pump due to short circuit in the system etc.
5) Air or Steam ratio setting is not proper:
For proper and efficient combustion, air fuel ration is very important, if the supply of air is excess then there will be excess of smoke, and if it exceeds more than normal level the combustion will burn off causing flame failure.
6) Flame eye is malfunctioning:
A Flame eye is a photocell operated flame sensor fitted directly on the refractory to detect weather the burner is firing or not. If the flame eye unit is malfunctioning, then it will give a trip signal even before the burner starts firing.
7) Forced draft fan flaps malfunctioning
For removing excess gases trapped inside the combustion chamber forced draft fan (FDF) are used for pre purging and post purging operation and are connected with a timer to shut the fan flaps. If the flaps are malfunctioning then continuous forced air will go inside the chamber, preventing the burner to produce flame causing flame failure of the boiler.
8) Any contactor switch inside Control panel is malfunctioning
Boiler control panel consist of several contactors and PLC cards. Even one contactor malfunctioning may result in trouble for boiler starting.
9) Trip not reset
If any previous trips like low water level, flame failure, emergency stop etc. has not been reset than boiler will not start.
10) Main Burner atomizer is clogged
Main burners consist of atomizer for efficient burning of fuel. If the atomizer is clogged by sludge and fuel deposits then burner may not produce flame and trip the boiler..
11) Pilot Burner nozzle is choked :
A Pilot burner nozzle is very small and can be blocked by carbon deposits and sludge resulting in flame failure. Some pilot burner consists of small filter which can be clogged after continuous operation resulting in flame failure because of carbon accumulation.
12) Electrodes are not generating spark
Initial spark for generating a flame is produced by electrode which may be due to carbon deposits on them or fault in the circuit of electrodes etc.